NYS-SORBER® AB 910
SKU: AB 910
A compliant thermal microwave absorber for EMI mitigation and heat transfer, with optical module applications described in the supplied data sheet.
Key Features
- Soft thermal gap filler format
- Thickness range: 0.5-5 mm
- Tacky, compliant surface
- UL 94 V-0
Response within 24 hours
Technical Data
Typical Properties
All values are typical and for reference only.Swipe horizontally to view all technical data.
| Property | Unit | Value | Test Method |
|---|---|---|---|
| Color | - | Gray | - |
| Hardness | Shore OO | 45±5 | ASTM D2240 |
| Density | g/cm³ | 4 | ASTM D792 |
| Permittivity ε’ (77GHz) | - | 13.6 | SJ20512-1995 |
| Permittivity ε” (77GHz) | - | 1.6 | SJ20512-1995 |
| Permeability μ’ (77GHz) | - | 1.1 | SJ20512-1995 |
| Permeability μ” (77GHz) | - | 0.06 | SJ20512-1995 |
| Working Temperature | °C | -45~+200 | ASTM D1329 |
| Volume Resistivity | Ω·cm | ≥10⁹ | ASTM D257 |
| Breakdown Voltage | kV | 4.5 | ASTM D149 |
| Flammability Rating | - | V-0 | UL94 |
| Thermal Conductivity | W/(m·K) | 1.8 | ASTM D5470 |
| Compression Ratio (30 psi) | % | 22.9 | - |
| Thermal Resistance (30 psi) | °C·in²/W | 0.78 | - |
| Compression Ratio (40 psi) | % | 27 | - |
| Thermal Resistance (40 psi) | °C·in²/W | 0.76 | - |
| Compression Ratio (10 psi) | % | 2.7 | - |
| Thermal Resistance (10 psi) | °C·in²/W | 0.97 | - |
| Compression Ratio (20 psi) | % | 13.1 | - |
| Thermal Resistance (20 psi) | °C·in²/W | 0.89 | - |
| Compression Ratio (2 psi) | % | 0.9 | - |
| Thermal Resistance (2 psi) | °C·in²/W | 1.05 | - |
| Compression Ratio (5 psi) | % | 1.9 | - |
| Thermal Resistance (5 psi) | °C·in²/W | 1.02 | - |
Specifications are subject to change without notice.
Download English TDS (PDF)
Overview
Product Introduction
A compliant thermal microwave absorber for EMI mitigation and heat transfer, with optical module applications described in the supplied data sheet.
Typical properties are reproduced from the supplied English data sheet, revision A1.0. Values are typical, for reference only. Refer to the complete data sheet for test conditions, curves and processing information. Evaluate suitability under actual application conditions.
Typical properties are reproduced from the supplied English data sheet, revision A1.0. Values are typical, for reference only. Refer to the complete data sheet for test conditions, curves and processing information. Evaluate suitability under actual application conditions.
Use Cases