NYS-SORBER® AB 1000
SKU: AB 1000
A silicone-based absorber and thermal interface pad for simultaneous EMI mitigation and heat transfer between a heat source and heat sink.
Key Features
- Soft, compliant pad
- Thermal conductivity: 10 W/(m·K)
- Thickness range: 0.5-5 mm
- Tacky surface; no peel-and-stick adhesive required when used as a thermal interface
- UL 94 V-0
Response within 24 hours
Technical Data
Typical Properties
All values are typical and for reference only.Swipe horizontally to view all technical data.
| Property | Unit | Value | Test Method |
|---|---|---|---|
| Color | - | Gray | - |
| Resin System | - | Silicone | - |
| Hardness | Shore OO | 55+/-5 | ASTM 2240 |
| Density | g/cm³ | 3.4 | ASTM D792 |
| Working Temperature | °C | -45~+150 | ASTM D1329 |
| Volume Resistivity | Ω·cm | ≥10⁹ | ASTM D257 |
| Breakdown Voltage | kV | 4.5 | ASTM D149 |
| Flammability Rating | - | V-0 | UL94 |
| Thermal Conductivity | W/(m·K) | 10 | ASTM D5470 |
| Thermal Resistance (2 mm, 10 psi) | °C·in²/W | 0.25 | ASTM D5470 |
| Thermal Resistance (2 mm, 20 psi) | °C·in²/W | 0.21 | ASTM D5470 |
| Thermal Resistance (2 mm, 30 psi) | °C·in²/W | 0.18 | ASTM D5470 |
| Thermal Resistance (2 mm, 40 psi) | °C·in²/W | 0.15 | ASTM D5470 |
| Thermal Resistance (2 mm, 50 psi) | °C·in²/W | 0.13 | ASTM D5470 |
Specifications are subject to change without notice.
Download English TDS (PDF)
Overview
Product Introduction
A silicone-based absorber and thermal interface pad for simultaneous EMI mitigation and heat transfer between a heat source and heat sink.
Typical properties are reproduced from the supplied English data sheet, revision A1.0. Values are typical, for reference only. Refer to the complete data sheet for test conditions, curves and processing information. Evaluate suitability under actual application conditions.
Typical properties are reproduced from the supplied English data sheet, revision A1.0. Values are typical, for reference only. Refer to the complete data sheet for test conditions, curves and processing information. Evaluate suitability under actual application conditions.
Use Cases