NYS-SEALOR® COE 601
SKU: COE 601
A co-extruded gasket combining conductive and non-conductive elements in one profile for EMI shielding and environmental sealing.
Key Features
- Dual conductive and sealing elements
- Low outgassing
- Working temperature: -55 to +170 °C
- Custom profile options shown in the data sheet
Response within 24 hours
Technical Data
Typical Properties
All values are typical and for reference only.Swipe horizontally to view all technical data.
| Property | Unit | Value | Test Method |
|---|---|---|---|
| Binder (conductive) | - | ECE 501 | - |
| Binder (non-conductive) | - | SR 300 | - |
| Conductive Particle (conductive) | - | Ag/Al | - |
| Hardness (conductive) | Shore A | 65 | ASTM D2240 |
| Hardness (non-conductive) | Shore A | 55 | ASTM D2240 |
| Density (conductive) | g/cm³ | 2.2 | ASTM D792 |
| Density (non-conductive) | g/cm³ | 1.2 | ASTM D792 |
| Volume Resistivity (conductive) | Ω·cm | 0.008 | MIL-DTL-83528C |
| Tensile Strength (conductive) | PSI | 180 | ASTM D412 |
| Tensile Strength (non-conductive) | PSI | 900 | ASTM D412 |
| Elongation (conductive) | % | 150 | ASTM D412 |
| Elongation (non-conductive) | % | 300 | ASTM D412 |
| Tear Strength (conductive) | PPI | 30 | ASTM D624 |
| Tear Strength (non-conductive) | PPI | 60 | ASTM D624 |
| Shielding Effectiveness (500 MHz, conductive) | dB | 110 | MIL-DTL-83528C |
| Shielding Effectiveness (2 GHz, conductive) | dB | 105 | MIL-DTL-83528C |
| Shielding Effectiveness (18 GHz, conductive) | dB | 100 | MIL-DTL-83528C |
| Working Temperature | °C | -55~+170 | ASTM D1329 |
Specifications are subject to change without notice.
Download English TDS (PDF)
Overview
Product Introduction
A co-extruded gasket combining conductive and non-conductive elements in one profile for EMI shielding and environmental sealing.
Typical properties are reproduced from the supplied English data sheet, revision A1.0. Values are typical, for reference only. Refer to the complete data sheet for test conditions, curves and processing information. Evaluate suitability under actual application conditions.
Typical properties are reproduced from the supplied English data sheet, revision A1.0. Values are typical, for reference only. Refer to the complete data sheet for test conditions, curves and processing information. Evaluate suitability under actual application conditions.
Use Cases